Operating Temperature | -30°C to +50°C |
---|---|
Operating Humidity | 0-95% RH, non-condensing |
Power Requirements | 100-240 VAC, 50/60 Hz |
Weight | 24 kg (53 lbs) |
Data Storage | Internal memory, USB, or network |
Communication | RS-232, USB, Ethernet |
Outputs | Analog, digital, USB, Ethernet |
Explains the radiometric principle of beta attenuation and particle detection.
Lists technical specifications for safety, source, detector, system configuration, performance, flow, and data storage.
Procedures for evaluating out-of-box performance, performing calibrations, and familiarizing with the menu.
Details siting the monitor, installing the inlet system, connecting devices, and setting datalogging.
Step-by-step procedure for turning on and initializing the instrument.
Key operational DOs and DON'Ts for safe and effective use.
Describes the graphics liquid-crystal display (LCD) for showing sample concentrations and parameters.
Contains items to control various instrument operational parameters.
Provides flexibility in how data is stored and recorded.
Recommends annual calibration and periodic quality checks.
Describes the preferred order of calibration for optimal performance.
Used to view and set the mass calibration point.
Read safety precautions before beginning any procedures in this chapter.
Procedure to replace the filter tape in case of breaks or if tape runs out.
Verifies no leaks using a volumetric flow meter and custom leak check adapter.
Read safety precautions before performing any actions listed in this chapter.
Guides designed to help isolate and identify instrument problems.
Board-level connection diagrams for common electronics and measurement system.
Read safety precautions before beginning any procedures in this chapter.
Procedure to replace the detector/preamplifier assembly.
Calibrates analog input channels to zero volts and full-scale.
Lists the hardware components of the Model 5028i.
Details electronic operation, power supplies, and component interconnections.
Controls external devices like analog output, input, and digital I/O.
Inlet configurations for monitoring different particle size fractions.
Provides convenient connection to instruments via numbered terminals.
Describes how the analyzer can be installed (bench or rack).
Explains command structure, modes, and error responses.
Lists C-Link protocol commands and their corresponding pages.
Communication parameters for configuring serial port to support MODBUS RTU protocol.
Describes various function codes supported by the Model 5028i.
Communication parameters for configuring serial port to support Gesytec protocol.
Explains the basic structure of a Gesytec command.
Lists ESM commands supported for the Model 5028i.