6.1 Error messages Hydraulic module
6 Hydraulic module
Error no. / picture Text Cause Fix
TX0101 NTC coffeeboiler open Problem with NTC in coffee boiler Check NTC and if necessary
exchange
TX0115
Flow error Too low water ow 1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check owmeter
5. Check pump
TX0116
Overtime error Product is not dispensed correctly
because of too low water ow
1. Dispense product again
2. Check owmeter
3. Check pump
TX0125
Waterow error No water pressure or owmeter
defective
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check owmeter
5. Check pump
TX0141
NTC coffee boiler short-circuit NTC on coffee boiler had a short
circuit
Change NTC on coffee boiler
TX0151
No waterow detected No water pressure or owmeter
defective
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check owmeter
5. Check pump
TX0154
Milk pump: no pulse Milk pump not recognised
TX0155
Water pump: no pulse Milk pump not recognised
TX0161
Please wait Machine rinses Wait until rinse is nished
TX0201
Cold start rinse
Please press rinse key
Rinse for start- and warm-up of
machine
Press rinse key