EasyManua.ls Logo

Thermoplan Black&Whute3 CT - Service Menu and System Check; Entering the Service Menu; System Check Inputs; System Check Outputs

Thermoplan Black&Whute3 CT
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REV-1
6.7
SECTION 6
© 2011 by Thermoplan AG, Änderungen vorbehalten
Technical manual
2. Service menu „System Check“
2.1 Entering the service menu
To enter the different service levels, follow these steps:
1. Push and hold left top corner.
2. The „Enter PIN“ window appears. Enter code and conrm with
.
The service menu can always be left by pressing the top left corner of the display.
23
1
56
4
89
7
Enter PIN
******
3. Following screen appears:
There are two different codes which each provide another programming level in the software:
User level: Code 111111
In the user level only few settings like product parameters, datetime and language can be set.
Technician level: Code 137900
In the technician level all settings can be looked-up and set.