SECTION 6
© 2011 by Thermoplan AG, Änderungen vorbehalten
Technical manual
2. Service menu „System Check“
2.1 Entering the service menu
To enter the different service levels, follow these steps:
1. Push and hold left top corner.
2. The „Enter PIN“ window appears. Enter code and conrm with
.
The service menu can always be left by pressing the top left corner of the display.
7
Enter PIN
******
3. Following screen appears:
There are two different codes which each provide another programming level in the software:
User level: Code 111111
In the user level only few settings like product parameters, datetime and language can be set.
Technician level: Code 137900
In the technician level all settings can be looked-up and set.