6
Tag Feeder Manual
HMI Displays
Press the F1 key to jog the feed motor. – This will incrementally advance
tags from the stack and into the discharge and eventually out of the dis-
charge. While jogging, ensure that only one tag is coming out at a time and
that there is at least 1” spacing between each tag.
If tags are coming out in doubles, lower the separators CCW another ¼ turn.
Press the up arrow key to increase the delay time for the start of the tag feed
after the trigger sensor is made. – This value will vary based on the speed of
the system. When running slow, the value will be higher than when running
fast.
With Miss FLT on, the machine will go into an error state when multiple
triggers have come into the machine before the rst cycle was completed.
Press F2 to turn on or off.
Press ESC to return to RUN SCREEN.