Control Module Time-Out Reprogramming
1. Press the small button and large right button (close) at
the same time for approximately 10 seconds. Pressing
these buttons at the same time will cause the module to
enter the time out programming mode. After entering
programming mode, the led will flash and the number of
flashes represents the timing cycle it is in per the
following table.
LED
Flash
Timing cycle before auto shutdown
1
On Indefinitely
2
2 minute on time
3
4 minute on time
4
6 minute on time
5
8 minute on time
6
10 minute on time
2. To increase the flashes press the left large button (open)
and to decrease the flashes press the large right button
(close). The LED will flash after pressing one of the
buttons to represent the new timing cycle. The unit
times out of programming mode after 10 seconds of no
activity.
The above instructions only apply to Rev14 RF modules (the rev number
is located on the inside surface of the module). Prior to this, the
modules were not programmable.