Injection Molding Machine Chapter 6
V3.0
6-10
4.2 Grease lubrication
Setting Of Lub. Counter Can Be Varied By Divide The % Of Clamp Tonnage.
b. See The Table 1, The Lub. Time Is 25sec.
The 250E, Time Of Used Is 1 Year & Clamp Is 200T (200T/250T=80%).
2.Depending On Clamp Tonnage And Cycle Time Of Each Case.
1.cSt150~250 Oil Is Recommend For Toggle Lubrication.
3.For Example:
Note:
Recommend Setting For Toggle Lub. Counter & Time
The Lub. Counter Is 118 80%=148.
a. See The FIG 1, 350day B Point D Point =118,
CA