Injection Molding Machine Chapter 3
V3.0
3-9
7 Preparation for operation
7.1 Power supply
To meet the power requirement in different countries and
areas
,
we provide machines with different voltage
rating
,
please confirm the voltage specification of the
machine prior to operation.
◇
An independent circuit breaker(NFB) hooked up with
the power supply shall be used to provide power for the
machine.
CE-type cabinet
Standard type
A) It is very important to hook up the grounding wire with terminal “
G
” in the
electrical control box.
B) Size of each wire R
,
S
,
T
,
N
,
G have to conform to the specification(as shown
in the table below)
C) Confirm that the voltage conforms to the operation voltage of the machine.
D) N
,
G must be connected independently.
Caution
E) Size of N
,
G should be at least half size of R
,
S
,
T
,
same size is preferred.
Model Motor (kW) Heating(kW) Breaker (NFB) Wire section area (mm
2
)
60E 11.2 5.5 75A(50A) 20(14)
90E 15 6.3 75A(50A) 20(14)
120E 18.75 8.2 100A(60A) 30(14)
150E 22.5 9.3 125A(75A) 38(22)
200E 30 15 150A(100A) 50(30)
250E 37.5 19.2 200A(125A) 80(50)
350E 45 32 350A(200A) 150(100)
500E 56 41 400A(250A) 250(125)
750E 75 50 500A(300A) 325(200)
1000E 112 82 800A(500A) 500(400)
※
Figures shown in Table above are for 220V/60HZ Figures in ( ) are for 380V/50HZ
※
Power supply voltage must be within 0.9~1.1 nominal voltage, and frequency tolerance is
0.99~1.01.