[SUMMING mode: OFF] (at CHANNEL LINK: OFF)
[SUMMING mode: ON (OUT=CH1+CH2) ] (at CHANNEL LINK: ON)
Step 1. Perform system settings.
Press the SETTING key to enter the system setting screen
(adjustment mode), then select the setting item with the
PARAMETER knob. (See p. 10; System setting flow chart.)
1-1. Set the adjustment mode.
Setting parameter: NORMAL or ADVANCED
The ADVANCED mode has more manually-operated setting
items than the NORMAL mode, enabling fine settings.
1-2. Set the SUMMING mode.
Setting parameter: OFF or OUT = CH1+CH2
The diagrams below show the relationship between the
input/output and the ALC/ANC functions when the
SUMMING mode is ON (OUT = CH1+CH2) and that when
the SUMMING mode is OFF.
1-3. Set the CHANNEL LINK.
Setting parameter: ON or OFF
Setting the CHANNEL LINK to ON permits both CH1 and
CH2 to be linked for each ON/OFF setting of the ALC and
ANC functions.
In this case, the input levels on CH1 and CH2 are ALC-
controlled at the same level.
[CHANNEL LINK: OFF] (at SUMMING mode: OFF)
[CHANNEL LINK: ON] (at SUMMING mode: OFF)
1-4. Set the SENSOR input sensitivity.
Setting parameter: +4 dB or –48 dB
1-5. Set the SENSOR input characteristics.
Setting parameter: A WEIGHT (A-weighted filter) or FLAT