Component Technical Manual TQM Meter for Fuel Dispensers
Document Ref 942175-001 Rev 3 Page 3-7
1
Calibration 3
OK
2 = 3
Ad
j
ust
Calibration 4
OK
Check
installation /
Replace
meter
(defective)
Sto
p
Yes
Yes
No
No
Yes
N
o
2
Calibration 3
OK
Ad
j
ust
Calibration 4
O
K
Check
installation /
Replace
meter
(defective)
No
N
o
N
o
Yes
Yes
OK = within acceptable
tolerance limits
Clean pump and
nozzle filter
Start
Run FP until
fuel comes
out of nozzle
Flush FP with
40 Liters
Calibration 1
OK
Calibration 2
OK
1 = 2
Ad
j
ust
1
Yes
Yes
Yes
No
No
2
3.6.1 FLUSHING AND CALIBRATION FLOWCHART.
The flowchart below illustrates the flushing and calibration instructions.