WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-33
Issue B
Display Explanations/comments
Volume/Amount Pulse menu.
voLAU
Press 8 to enter submenu.
Press 0 to exit OCB menu.
v o L U Volume Pulse submenu (number of pulses per cl).
Un I t Default 1 is flashing. Press 9 to increase this value (range 1 to 10
1
pulses/cl).
Press 7 to go to next submenu.
Press 0 to exit OCB menu.
v o L U Volume Pulse Width menu (*0.25ms).
PE r I od Default 5 is flashing. Press 9 to increase this value (range 5 to 40).
5
Press 7 to go to next submenu.
Press 0 to exit OCB menu.
A n n t Amount Pulse menu (amount of pulses per 0.01 amount units).
Un I t Default 1 is flashing. Press 9 to increase this value (range 1 to 10
1
pulses).
Press 7 to go to next submenu.
Press 0 to exit submenu.
P r o d X Product Position menu.
PoS Note : this menu only appears with certain configurations.
r1
Prod 1 or the product name (if programmed) is displayed.
r 1 is flashing (right/side A product 1).
Press 8 to select a product (right then left).
Press 9 to change the product position.
Repeat process until product positions have been set for all
available products.
Press 0 to exit OCB menu.

Table of Contents