KERNEL ERRORS
LIST OF PERIPHERAL TYPES
CC Component indication
AP Application
Gc Kernel
Hc HCM
Ho HOM
CS Customer Sales display
So Sound Option Module
UA User Access Module
Ec VRC
Oc Option Controller Board
S Subcategory of peripheral
HCM 0 General HCM error
e.g. totaliser, dispenser light, high speed valve
HCM 1-4 Related to product 1-4
HOM 1-4 Related to HOM with address 10-13
CSD 0 Master
CSD 1 Satellite/Slave
r Right/Side A
L Left/Side B
E,e Error/Event Code
nnnn No of deliveries since last delivery
Main event code
1 GENERAL ERROR application dependent
Main event code Sub event code
1 FUEL LEAK 1 FUEL_LEAK_ERROR
2 FUEL_LEAK_MAX_VOL
3 FUEL_LEAK_3_SEQ
2 VAPOUR LEAK 1 VAPOUR LEAK ERROR
3 CALCULATION_ERROR 1 INVALID UNIT PRICE
4 POWER ERROR 1 MAINS OFF
2BATTERY
3 POWER UP ONGOING DELIVERY
5 VAPOUR RECOVERY ERROR 1 VRC BLOCKED
12.3.3 DIAGNOSTIC DATABASE
The Diagnostic Log can be viewed in Maintenance Mode - refer to section 5.
The database only stores the last 100 events/errors occurred in the calculator.
The events/errors can be interpreted as follows:-
APPLICATION ERRORS (application dependent)