Page 5-10 Document Ref 905675-001 Rev 2
Set Up Modes WWC T1 Set Up & Maintenance Manual
Issue B
5.4 AFM Set Up Menu
5.4.1 NO ADDRESS CONFLICT
Display Explanations/comments
AF
AFM Set Up menu.
Se tUP
Press 7 to skip AFM set up - this will disable any AFMs.
If AFM is not set, any attempt to start a delivery will generate
error message 4 3 (pulser not connected).
Press 8 to enter this menu.
A F The AFM Scan menu is displayed and all connected AFMs are
S c A n automatically scanned and compared to the expected configuration
according to the selected set up and number of hoses (refer to
section 5.4.3).
The result of the scan will affect the following menus:-
- if no address conflict is detected, continue AFM set up
- if an address conflict is found, set the correct address
before continuing with AFM set up.
Display Explanations/comments
HoSE X
AFM Address menu (only if no address conflict is detected
rIGHt
during the scan.
AF y
X is the product/hose number as defined in the set up.
y is the AFM address (1 to 12) which is displayed if the AFM has
been correctly detected. If the AFM is missing or has an invalid
address then y will be blank.
Note : If more than one meter per hose e.g. SHS or more than one
hose per meter e.g. SAT, then both meters/hoses will appear in a
row with the appropriate hose/meter assignments - refer to section
5.4.3.
Press 8 to scroll through all AFMs as required.
Press 0 to re-scan.