Page 6-6 Document Ref 905675-001 Rev 2
Maintenance Modes WWC T1 Set Up & Maintenance Manual
6.5 Diagnostic Information (Error Log)
This menu provides access to the calculators error log where the error codes for each
error database can be viewed. The database stores the last 100 errors/events since the last
reset of the error log. For a detailed description, refer to Appendix C.
6.5.1 KERNEL VERSIONS > 01.07
Issue A
Display Explanations/comments
dIAG
L o G The Diagnostic Log function is displayed.
Press 8 to enter this menu.
n b o F The Error Log menu is displayed.
LoGS X = the total number of errors and events logged.
X
Press 0 to return to previous menu.
Press 7 to continue.
Er
X
The first error/event is displayed.
Hc
0rPress 7 to scroll through each error/event log until all errors have
6 1 been viewed and the previous menu is displayed again.
For a detailed description of error codes, refer to Appendix C.
Error Code:-
CS 1,2 = Master/Slave display
HC 1,2,3,4 = HCM error, product 1,2,3,4
HO 1,2,3,4 = HOM error, HOM unit 10,11,12,13
SO = Sound option module
UA = User Access module
EC = Vapour Recovery
OC = Option Controller Board
GC = Kernel error
AP = Application error (to be defined)
Press 0 to return to Diagnostic Log menu.
d I A G The Diagnostic Log Menu is displayed again.
LoG Press 7 to reset the error log.
r E S E t The reset error log menu is displayed.
LoG Press 9 to toggle between ye s and no .
no
Press 7 to save and continue.
Press 0 to return to Diagnostic Log menu.