WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-13
Issue A
6.10.3 ESSO LEAK DETECTION
When Esso Leak Detection is activated and a leak is detected, the calculator
will disable the associated dispenser which must be reset by user intervention
via this menu. The Flow Leak menu changes into:-
Display Explanations/comments
F L o d E t Fraud Sensor menu (country 33 and set ups 50,53,58,63 only).
SEnSo r Press 9 to toggle between yes and no.
no
Note : When set to yes, the fraud sensors are enabled and
cannot be disabled.
Press 8 to enter this menu.
F A L S F L Fraud Detection menu.
Pr
r1
The fraud status for all configured products can be viewed.
YES
Press 8 to increase the product number (right then left).
If yes is displayed then there has been a fradulent delivery for
the associated product. Press 9 to reset the value to no to
enable the associated product.
Press 7 to save and continue.
6.11 Fraud Detection Functionality
The Fraud Detection function enables the setting of fraud sensors and displays the
fraudulent status of each configured product.
Display Explanations/comments
E S L E A Esso Leak menu.
E r r o r The error must be reset to enable the dispenser.
on
Press 9 to toggle between on and off .
Press 7 to save and continue.