WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-27
6.29 AFM Menu
This menu will allow the configuration of Axial Flow volume meters.
6.29.2 AFM READ-ONLY MENU
This menu displays the current AFM settings in read-only mode.
6.29.1 AFM CHANGE MENU
Entering the change sub-menu will follow the same series of steps as described
in detail in section 5.4.
Issue B
(CONT.)
Display Explanations/comments
A F AFM Read only menu.
rEAd
Read is flashing.
Press 8 to enter this menu.
H o S E X AFM selection menu.
rIGHt Press 7 to view the display AFM characteristics.
AF y Press 8 to scroll through all connected AFMs (right then left).
d I S c o n Disconnected menu (only if AFM is not connected/initialised).
AF y
Press 7 to continue (all displays will be blank).
Press 0 to return to previous menu.
Display Explanations/comments
A F At the Maintenance menu, press 7 to scroll through the options
c o n F until the AFM Configuration menu is displayed.
Press 8 to enter this menu.
A F AFM Read menu.
rEAd
Press 7 to toggle between read (read-only access to AFM
settings) and change (change AFM settings).
Press 8 to enter read submenu (when read is displayed) or
change submenu (when change is displayed).
Press 0 to return to previous menu.