Automated Clinical Analyzer
Operators Manual
Ver.1.00
T
TOKYO BOEKI MEDISYS INC.
Original Instructions

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Tokyo Boeki Medisys BIOLIS 30I and is the answer not in the manual?

Tokyo Boeki Medisys BIOLIS 30I Specifications

General IconGeneral
TypeClinical Chemistry Analyzer
ModelBIOLIS 30I
ManufacturerTokyo Boeki Medisys
Reagent Positions30
Light SourceHalogen Lamp
Photometric Range0 - 3.0 Abs
Power SupplyAC 100-240V, 50/60 Hz
Operating Temperature15-30°C
Sample Volume2-30 µL
Reagent Volume20-300 µL
Wavelengths340, 405, 505, 546, 578, 660, 700 nm
Operating Humidity30 - 80% (non-condensing)
Throughputup to 240 tests/hour

Summary

Preface

Expression of Warning and Notice

Classification of safety warnings and descriptions of hazard symbols used.

Safety Caution • Caution in Operation

Detailed safety precautions and operational warnings for analyzer use.

Chapter 3 Explanation of each screen and operating condition

Start-up inspection

Pre-operation checks including water supply, reservoirs, and reagent levels.

Measurement condition (Item parameter) setting

Configuration of analysis parameters like units, wavelengths, and sample volumes.

Reagent bottle position setting

Procedure for setting reagent bottle positions and confirming tray configurations.

Reagent bottle setting

Steps for configuring reagent bottle information, including residual volume.

Calibration setting (Standard sample position, concentration)

Inputting calibration conditions like sample position and concentration.

Calibration order entry

Steps for ordering calibration blank and standard samples.

Calibration sample setting (Blank, Standard) and measurement

Setting and executing calibration measurements for blank and standard samples.

ISE Calibration sample setting and measurement

Procedure for setting and measuring ISE calibration samples.

QC measurement condition setting (Control setting)

Configuring Quality Control parameters like control name and measurement positions.

QC sample order entry

Steps for ordering QC samples and confirming their placement on the tray.

QC sample setting and measurement

Setting QC samples on the tray and initiating measurement.

Patient sample order entry

Inputting patient sample details and selecting test items for analysis.

Patient sample setting and measurement

Placing patient samples on the tray and starting the measurement.

Inspection and maintenance at the end of operation

Performing checks and maintenance tasks after daily operation.

Chapter 4 Explanation of each screen and operating condition

Order (Patient sample order entry) screen

Interface for entering patient sample details and selecting tests.

Calibration screen

Managing calibration settings, ordering, and viewing results.

QC screen

Configuring, ordering, and reviewing Quality Control samples and results.

Item screen

Setting analysis parameters for different test items like Optical, ISE, and HbA1c.

Maintenance screen

Accessing and performing various maintenance procedures for analyzer upkeep.

Chapter 5 Maintenance

Safety caution

Essential safety warnings and precautions to follow during maintenance.

Maintenance procedure

Step-by-step instructions for performing essential maintenance tasks.