! Page!52! "##$#$!
LED indications following “Power-On Self Test”:
Green
Amber
Red
'
Solid: Charging complete. Charger in
Maintenance Mode.
Flashing: Short:<80% Charge.
Long:>80% Charge.
When battery is not connected: Algorithm
Number display.
Flashing: Reduced Power Mode: Low AC Voltage or
High internal charger temperature.
Flashing: Charger error. Reset charger power and
refer to Troubleshooting below.
Maintenance Instructions
1. For flooded lead-acid batteries, regularly check water levels of each battery cell after charging and add
distilled water as required to level specified by battery manufacter. Follow the maintenance and safety
instructions recommended by the battery manufacturer.
2. Make sure charger connections to battery terminals are tight and clean.
3. Do not expose charger to oil, dirt, mud or direct water spray when cleaning vehicle.
Troubleshooting Instructions
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Causes
Solution
Battery High Voltage
Check battery size and condition and
reset charger (interrupt AC power for
15 seconds).
Battery Low Voltage
Check battery size and condition and
reset charger (interrupt AC power for
15 seconds).
Charge Timeout caused by
battery pack not reaching
required voltage. Charger
output was reduced due to high
temperatures
Check connections
Operate charger at a lower ambient
temperature.
Check Battery: battery could
not be trickle charged up to
minimum voltage
Check for shorter or damaged cells.
Over-Temperature: Charger
shut down due to high internal
temperature.
Ensure sufficient cooling air flow and
reset charger (interrupt AC power for
15 seconds).
Charger Internal Fault
Reset charger (interrupt AC power for
15 seconds). Return to qualified
service depot if fault persists.
!"#$%"&'()*#&+,$-&
.().&/0121344&5&6744&5&3844&5&9144
Installation Instructions
WARNING: The output of chargers with greater than 48V may