22
FIGURE - FIGURES
RR
#
Fig.
Schema di collegamento RR - con pulsante deviatore
Connection diagram for RR – with deviator key
9
SP1
J1
Dip-switch
F
N
A
1
2 3 4
ON
nero / blacknero / blacknero / black
grigio / graygrigio / graygrigio / gray
marrone / brownmarrone / brownmarrone / brown
blu / blu / blueblueblu / blue
bianco / whitebianco / whitebianco / white
Giallo / yellowGiallo / yellowGiallo / yellow
A
QUESTO SIMBOLO IDENTIFICA NEGLI SCHEMI DI
COLLEGAMENTO ELETTRICO L’ATTUATORE TOPP
IT
THIS SYMBOL IDENTIFIES THE ACTUATOR TOPP SPA
IN THE ELECTRICAL CONNECTION LAYOUTS.
EN
230V ~
P
O
C
LEGENDA:
P - Pulsante deviatore con
posizione “0” centrale
O - Apre
C - Chiude
IT
LEGEND:
P - Deviator key with central “0”
position
O - Open
C - Closed
EN