Problem Remedy
Machine does operate
Make sure air line valve is in ON position.
Inspect air regulators for interference of air ow.
Inspect air compressor for adequate size and that proper air pressure
is available (60 to 90 p.s.i.).
Inspect air line for proper size and/or damage.
Always use ow through connectors.
Machine stops running
Inspect drum level.
Inspect air line for damage.
Inspect air pressure.
Machine has no suction
Inspect for clogged or collapsed hose
Defective drum seal.
Material too heavy for unit.
Air pressure drops at gauge
Inspect air compressor for proper free air consumption and resis-
tance in air line size or connections.
Machine has poor recovery
Inspect for correct size hose and attachments.
Defective drum seal.
Material too heavy for unit.
Inspect external lter(s). Empty and clean if necessary.
Ensure external lter(s) are properly locked onto venturi powerheads.
Inspect drum cover gasket.
Ensure venturi powerheads are properly locked into Jumbo cover.
Inspect connection of external lters.
Inspect all seals for wear and/or damage.
https://harrissupplyind.com - To Order Parts Call 608-268-8080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tornado 95995 and is the answer not in the manual?

Tornado 95995 Specifications

General IconGeneral
BrandTornado
Model95995
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals