Injection Pump (ETR) Solenoid (Reelmaster 216-D only) (Fig. 19)
The Reelmaster
®
216-D has an energize-to-run (ETR)
fuel stop solenoid mounted on the engine block next to
the fuel injection pump with a purple wire attached. The
solenoid will stop injector pump fuel delivery with any
electrical failure in the RUN circuit.
1. Disconnect the wire from the solenoid.
2. Remove the solenoid from the injector pump.
3. Connect a 12 volt battery so that a wire from positive
(+) battery terminal is connected to switch terminal.
Touch a wire from the negative (–) battery terminal to
solenoid body. The plunger should retract.
1
Figure 19
NOTE: You can also test operation without removing the
solenoid from the injector pump. Listen for an audible
1. Fuel stop solenoid
“click” as the solenoid extends and retracts while doing
step 3 of the above procedure. This will not show if the
solenoid is fully extending and retracting.
Testing Page 6 - 26 Reelmaster
®
216/216-D