FaultsScreen
g202792
Figure78
1.Left/rightbutton
4.Faultitems
2.Downbutton5.Faultmenu
3.Menu/backbutton
Thefaultsscreen(Figure78)willlistallthemachineelectricalfaultsthathave
occurredsincethefaultswerelastclearedfromtheInfoCenter.Thefaultswillbe
identiedbyanumberandwhenthefaultoccurred.Thefaultsthatmightoccur
ontheeFlexmachinearelistedintheFaultT able(page5–26).
TheInfoCenterfaultlogcanbeclearedbyselectingtheclearsystemfaults
menuitem.TheclearedfaultswillberemovedfromtheInfoCenterbutwillbe
retainedintheTECmemory.
Ifafaultoccursduringmachineuse,theremaybeachangeinmachine
functionalityduetothefault.Shouldtherebemachineoperationissuesdue
toafault,arststeptoremedytheissuewouldbetomovethetractionlever
totheNEUTRALposition,turnthekeyswitchtotheOFFposition,andallowall
themachinefunctionstostop.Then,attempttorestartthemachinetoseeif
operationhasreturnedtonormal.Somefaultswillberesetduringtherestart
andwillthenallownormalfunction.Ifafaultcontinuestooccur,furthersystem
evaluationandpossiblecomponentrepairorreplacementwillbenecessary.
Toreturntothemainmenuscreenfromthefaultsscreen,pressthemenu/back
button(asindicatedbythe
atthebottomofthescreen).
FaultTable
FaultIdentication
FaultDescription
#1InternalTECfault
#212VDCsupplyfault
#35VDCsupplyfault
#4Lithiumbatterypackbusfault
#5CAN-buscommunicationfault
#6Motorovercurrentfault*
#7Motorovertemperaturefault
#8Motoroverspeedfault*
#9Internalelectricmotorfault
ElectricalSystem:InfoCenterDisplay
Page5–26
Greensmaster
®
eFlex1800,2100and2120
12189SLRevE