ELECTRICAL
6-6
Toro 30” Aerator Service Manual
6
Relay
Purpose
There are two relays on this machine.
1. Start Relay: Functions as an electronic switch.
Once the safety connections are met, the relay will
activate completing the circuit to the starter solenoid.
2. Stop Relay: Functions as an electronic switch.
Once the safety connections are met, the relay will
activate completing the circuit to the MAG KILL and
the fuel solenoid, which stops the engine and stops
fuel ow.
Location
The relays are located on the frame, right side of the
engine, under the fuel tank (Fig. 234).
Fig. 234 002
How It Works
Hours are accumulated when the key is in the on/run
position or the start position.
Testing
If the hour meter isn’t working, disconnect the hour
meter positive wire. Turn the key to on/run and check
for voltage to the positive wire. If voltage is present, the
meter is faulty.
Fig. 233 control panel
Hour Meter
Purpose
The hour meter keeps track of the actual running hours
of the engine.
Location
The hour meter is located on the control panel (Fig.
233).