HYDRAULIC DRIVE SYSTEM
6-82 Toro GrandStand Service Manual
6
11. Install the low pressure return line to the 45 degree
tting and secure with the hose clamp (Fig. 1202).
Fig. 1202 IMG-0892a
12. Secure the hose to the reservoir bracket using the
“R” clamp, bolt, washer and nut (Fig. 1203).
Fig. 1203 IMG-0821a
13. Fill the reservoir to the “COLD” uid level (Fig.
1204).
14. Bleed the hydraulic system. See “Bleeding the
Hydraulic System” on page 6-95.
A. Cap C. Cold uid level-full
B. Bafe D. Hot uid level-full
Fig. 1204 g. 68 G001045
A
B
D
C