TestingtheStarterSolenoid(continued)
7.Whentestingiscomplete,securethecablesandwirestothesolenoid.
Tightenthenutsonthesolenoidcoilpostsfrom15to20in-lb(1.7to2.3
N∙m).Tightenthenutsonthemaincontactpostsfrom50to60in-lb(5.7
to6.8N∙m).
8.Connectthepositive(+)cabletothebatteryrstandthenconnectthe
negative(-)cabletothebattery.Coatthewireandcableconnectionsatthe
batteryandatthestartersolenoidwithBatteryTerminalProtector(page5–3).
Greensmaster3120
Page5–15
ElectricalSystem:TestingtheElectricalComponents
17230SLRevC