HydraulicSystem
Maintenance
ChangingtheHydraulicOil
andFilter
ServiceInterval:Aftertherst50hours
Every800hours
Iftheoilbecomescontaminated,contactyourlocal
Torodistributorbecausethesystemmustbeushed.
Contaminatedoillooksmilkyorblackwhencompared
tocleanoil.
1.Cleantheareaaroundtheltermountingarea
(Figure52).Placeadrainpanunderthelter
andremovethelter.
Note:Iftheoilisnotgoingtobedrained,
disconnectandplugthehydrauliclinegoingto
thelter.
g014619
Figure52
1.Hydraulicoillter
2.Fillthereplacementlterwiththeappropriate
hydraulicuid,lubricatethesealinggasket,and
handturnituntilthegasketcontactsthelter
head.Thentighten3/4turnfurther.Thelter
shouldnowbesealed.
3.Fillthehydraulicreservoirwithhydraulicoil;refer
toCheckingtheHydraulicFluidLevel(page25).
4.Startthemachineandrunitatidlefor3to5
minutestocirculatetheuidandremoveanyair
trappedinthesystem.
5.Stopthemachine,rechecktheuidleveland
replenishasrequired.
6.Disposeoftheoilandlterproperly.
CheckingtheHydraulic
LinesandHoses
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
Makesureallhydraulicuidhosesand
linesareingoodconditionandallhydraulic
connectionsandttingsaretightbefore
applyingpressuretothehydraulicsystem.
Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthatejecthigh
pressurehydraulicuid.
Usecardboardorpapertondhydraulic
leaks.
Safelyrelieveallpressureinthehydraulic
systembeforeperforminganyworkonthe
hydraulicsystem.
Getimmediatemedicalhelpifuidis
injectedintoskin.
Checkthehydrauliclinesandhosesdailyfor
leaks,kinkedlines,loosemountingsupports,wear,
loosettings,weatherdeterioration,andchemical
deterioration.Makeallnecessaryrepairsbefore
operating.