Greensmaster 3300/3400 Page 6 -- 9 Electrical System
Retrieving Fault Codes
All machinefault codes areretained in theTEC control-
ler memory. The three (3) most recent fault codes that
have occurred w ithin the last forty (40) hours of opera-
tion can be retrieved using the diagnostic light. To re-
trieve these fault codes from the controller memory,
perform the following switch sequence:
1. Operator seat should be UNOCCUPIED.
2. Place functional control lever in the TRANSPORT
position.
3. Make sure that backlap valve on mow control man-
ifold is in the MOW position.
4. Move and hold joystick in the RAISE position.
5. Turn ignition switch to the RUN position.
6. Monitor the diagnostic light for fault code(s).
NOTE: Once thediagnostic lightbegins todisplay fault
codes, the joystick can be released.
Fault codes displayed by the diagnostic light consist of
atwodigitnumber.Faultcodesarelistedinthechartbe-
low. There will be a one (1) second pause between the
first and second digit of a code. Up to three (3) fault
codesretainedincontrollermemorywillbedisplayedby
thediagnostic lightin orderfrom themostrecentfaultto
the oldest fault. If there are multiple faults in controller
memory,therewillbeathree(3)secondpausebetween
codes.Thefaultcodeswillcontinuallyrepeatafterafive
(5) second pause until the ignition key is turned off.
If there are no faults that have occurred within the last
forty (40) hours of operation, the diagnostic light will
flash continuously after performing the above fault re-
trieval switch sequence.
Ifafaultcodeisnotretrievedfromthecontrollermemory
within forty (40) hours of machine operating time, the
fault cannot be retrieved from controller memory using
this procedure. If necessary, contact your Toro distribu-
tor to retrieve older fault codes.
Fault Code (Lamp Flashes)
Fault Description
2--1 Controller has been replaced causing machine identification to be in error
2--9 TEC controller is faulty
3--1 Coolant sensor is faulty
3--2 Excessive engine temperature has caused engine shutdown
3--7 Current to fan relay is excessive
3--9 TEC controller is faulty
4--3 Optional hydraulic oil temperature sensor is faulty (GR3400)
4--7 Current to console high temperature warning light is excessive (GR3400)
5--2 Engine alternator voltage output is excessive
5--4 Right fuse 2 (7.5 amp) for TEC outputs is faulty
5--5 Right fuse 3 (7.5 amp) for TEC outputs is faulty
5--6 Right fuse 4 (7.5 amp) for TEC outputs is faulty
5--7 Current to leak detector alarm (GR3300) or glow relay (GR3400) is excessive
6--4 Main power relay is faulty
6--7 Current to solenoid coil S1 (lift/lower manifold) is excessive
7--1 Current to solenoid coil S2 (lift/lower manifold) is excessive
7--4 Current to solenoid coil S3 (lift/lower manifold) is excessive
7--6 Current to solenoid coil S4 (lift/lower manifold) is excessive
7--8 Current to solenoid coil PRV (mow manifold) is excessive
8--1 Current to start relay is excessive