Greensmaster 3300/3400Page 6 -- 30Electrical System
Hour Meter
1. Park machineon alevel surface,lower cuttingunits,
engage parking brake and stop engine. Remove key
from ignition switch.
2. Remove console cover from console assembly to
gain access to hour meter (see Control Console Disas-
sembly in the Service andRepairs section of Chapter 7
-- Chassis).
3. Disconnectmachinewireharnesselectricalconnec-
tor from the hour meter.
4. Connectthepositive(+)terminalofa12VDCsource
to the positive terminal of the hour meter.
5. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
6. The hour meter s hould move 1/10 of an hour in six
(6) minutes.
7. Disconnect the voltage source from the hour meter.
8. Replace the hour meter if necessary.
9. Connect harness electrical connector to the hour
meter.
10.After testing iscomplete, connectmachine wire har-
nessconnectortothehourmeter.Secureconsolecover
to machine with removed fasteners.
1. Control console 2. Hour meter
Figure 29
2
1
Figure 30