EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Page 229

Toro Greensmaster TriFlex 3400
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Greensmaster 3300/3400 Page 6 -- 59 Electrical System
Battery Charging
To minimize possible damage to the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished with a constant current battery charger
which is available in most shops.
CAUTION
Follow the battery charger manufacturer ’s
instructions when using a battery charger.
NOTE: Using specific gravity of the battery cells is the
mostaccurate methodofdetermining batterycondition.
1. Determine the battery charge level from either its
specific gravity or open circuit voltage.
Battery Charge
Level
Specific
Gravity
Open Circuit
Voltage
100% 1.265 12.68
75% 1.225 12.45
50% 1.190 12.24
25% 1.155 12.06
0% 1.120 11.89
2. Determinethechargingtimeandrateusingthebat -
tery charger manufacturers instructions or the fol-
lowing table.
Battery
Reserve
C
a
p
a
c
i
y
Battery Charge Level
(Percent of Fully Charged)
C
a
p
a
c
i
y
(Minutes)
75% 50% 25% 0%
80 or
less
(GR3300)
3.8 hrs
@
3amps
7.5 hrs
@
3amps
11.3 hrs
@
3amps
15 hrs
@
3amps
81 to 125
(GR3400)
5.3 hrs
@
4amps
10.5 hrs
@
4amps
15.8 hrs
@
4amps
21 hrs
@
4amps
126 to
170
5.5 hrs
@
5amps
11 hrs
@
5amps
16.5 hrs
@
5amps
22 hrs
@
5amps
171 to
250
5.8 hrs
@
6amps
11.5 hrs
@
6amps
17.3 hrs
@
6amps
23 hrs
@
6amps
above
250
6hrs
@
10 amps
12 hrs
@
10 amps
18 hrs
@
10 amps
24 hrs
@
10 amps
CAUTION
Donotchargea f rozen batterybecause it canex-
plode and cause injury. Let the battery warm to
60
o
F(16
o
C) before connecting t o a charger.
Charge the battery in a well--ventilated place to
dissipate gases produced from charging. These
gases are explosive; keep open flame and elec-
tricalsparkaway fromthe battery.Donotsmoke.
Nausea may result if the gases are inhaled. Un-
plug the chargerfrom theelectrical outletbefore
connecting or disconnecting the charger leads
from the battery posts.
3. Following the battery charger manufacturers
instructions,connectthechargercablestothebattery.
Make sure a good connection is made.
4. Charge the battery following the battery charger
manufacturers instructions.
5. Occasionally check the temperature of the battery
electrolyte.If thetemperatureexceeds 125
o
F(52
o
C)or
the electrolyte is violently gassing or spewing, the
charging rate must be lowered or temporarily stopped.
6. Three(3)hourspriortotheendofthecharging,mea-
sure the specific gravity of a battery cell once per hour.
The battery is fully charged when the cells are gassing
freely at a low charging rate and there is less than a
0.003 change in specific gravity for three consecutive
readings.