EasyManua.ls Logo

Toro GROUNDSMASTER 325-D - Nozzle Leakage Test (Mitsubishi K3 D)

Toro GROUNDSMASTER 325-D
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TORO GM 325-D Mitsubishi K3D Diesel Engine
Notes
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
________________________________________________________________________________________________________________
31
1. Nozzle Leakage Test.
The leakage test checks the nozzle tip for proper sealing.
A leaking nozzle should be repaired or replaced.
2. Operate the pump until 1500 psi (108 kg/cm²) is reached, maintain this pressure.
3. Check the nozzle end.
If the nozzle end is dry or a slight film of fuel is present, the nozzle is OK.
If a drop of fuel forms or the nozzle drips fuel, the nozzle must be serviced or replaced.