Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
•Makesureallhydraulicuidhosesand
linesareingoodconditionandallhydraulic
connectionsandttingsaretightbefore
applyingpressuretothehydraulicsystem.
•Keepyourbodyandhandsawayfrompin
holeleaksornozzlesthatejecthighpressure
hydraulicuid.
•Usecardboardorpapertondhydraulic
leaks.
•Safelyrelieveallpressureinthehydraulic
systembeforeperforminganyworkonthe
hydraulicsystem.
•Seekimmediatemedicalattentionifuid
isinjectedintoskin.
HydraulicSystemTestPorts
Thetestportsareusedtotestthepressureinthe
hydrauliccircuits.ContactyourlocalTorodistributor
forassistance.
TestPortA(Figure70),locatedontheleftsideof
themachine,isusedtomeasuretheforwardtraction
pressure.
Figure70
1.TestportA
TestPortB(Figure71),locatedontherightsideof
themachine,isusedtomeasurethereversetraction
pressure.
Figure71
1.TestportB
TestPortC(Figure72),locatedontheleftsideofthe
machine,isusedtomeasuretheleftcuttingunitpressure.
Figure72
1.TestportC
TestPortD(Figure73),locatedontherightsideof
themachine,isusedtomeasuretherightcuttingunit
pressure.
Figure73
1.TestportD
TestPortE(Figure74),locatedundertheradiator,is
usedtomeasurethefour-wheeldrivepressureinreverse.
50