Multi Pro 1200/1250 Page 3 -- 13 Kohler Gasoline Engine
6. Install choke cable to engine and secure with cable
clamp (Figs. 9 and 10). Check choke cable adjustment
(see Adjust Choke Cable in the Adjustments Section of
this chapter).
7. Reconnect accelerator cable to engine (Figs. 9 and
10).
A. Position accelerator cable to the engine speed
control bracket.
B. Slide the sleeve back on the cable ball joint and
placecableballjointonballstud. Release thesleeve
so it slides over the stud to secure cable.
C. T ighten cable jam nuts that secure accelerator
cable to control bracket.
8. If fuel line was removed, route fuel line through R--
clamps on mounting plate. Connect fuel line to the fuel
pump and secure with clamp.
9. Positionoilfilteradapterwithoilfiltertotherighthand
frame rail. Install two (2) flange head screws and flange
nuts and secure oil filter adapter to machine (Fig. 11).
10.Reinstall the muffler section of the exhaust system
(see Exhaust System Installation in this section).
11.Ifhydraulichosesweredisconnected,make surehy-
draulic hoses and pump ports areclean. Remove plugs
and caps from pump andhoses thatwere placedduring
disassembly. Install hydraulic hoses to steering pump.
12.Check engine oil level and transaxle/hydraulic fluid
level (see Operators Manual).
13.Connect positive (+) and then negative (--) battery
cables to the battery.
14.Check engine speed (see Adjust Engine Speed in
the Adjustments Section of this chapter).