Page 10 -- 9
Spray Circuit
Power Current
Control Current
Indicator/Gauge Current
Multi Pro 1200
Pump Switch ON
(LOWER)
(RAISE)
(LOWER)
(RAISE)
(OPTIONAL KIT)
(ENERGIZED)
(ENERGIZED)
NOTE: WHEN THE PUMP SWITCH IS PRESSED
TO THE MOMENTARYON POSITION, SWITCH
TERMINALS 5AND 6ARE USED TO INITIALLY
ENERGIZE THE PUMPRELAYANDALSO TO CREATE
ALATCHCIRCUIT THROUGH SWITCH TERMINALS
2AND 3. THIS LATCH CIRCUITKEEPS THE PUMP
RELAYENERGIZEDAS SHOWN.
RIGHTBOOM
ACTUATOR
LEFTBOOM
ACTUATOR