UsingtheOnboardDiagnosticLamp
Machineswithwirelesshandheldremotecontrol(Models44552,44552TE,and
44553)haveadiagnosticlightlocatedonthecontroltowerbelowthehourmeter.
ThediagnosticlightisanoutputoftheT oroElectronicController(TEC)that
indicatesnormalmachineoperationorthepresenceofactivemachinefaults.
AfteryouturnthekeytotheRUNposition,thediagnosticlightilluminatesfor5
seconds,turnsofffor5seconds,andthenashesuntilyoustarttheenginewith
thekeyswitchorpushabuttononthehandheldremote.
Thediagnosticlightwillashrapidlyifnosignalfromthehandheldremotehas
beenreceivedwithin10secondsofsettingthekeyswitchtotheRUNposition,
ifthehandheldremoteisoutofrange,haslowbatteries,orisnotassociated
totheRF2CANmodule.Thediagnosticlightshouldilluminatewhileabutton
onthehandheldremoteispressed.
IfthekeyswitchissettotheRUNpositionandthediagnosticlightturnsonfor5
secondsthenstartsashingrapidly(withorwithoutapause)anactivemachine
faultexists.
g279310
Figure6
1.Controltower3.Shuntconnectors
2.Diagnosticlight4.Tetheredcap
EnteringDiagnosticMode
1.SetthekeyswitchtotheOFFposition.
2.Locatethediagnosticshuntconnectors,removethetetheredcapand
connecttheshuntconnectorstogether.
3.SetthekeyswitchtotheRUNposition.
4.Countandrecordtheashpatternofthediagnosticlight.
ProForce®DebrisBlower
Page3–3
Troubleshooting:GeneralOperationProblems
18237SLRevA