EnteringDiagnosticMode(continued)
Note:Iftherearemultiplemachinefaultsactive,eachfaultwillashfollowed
byalongpause.Aftereachactivefaultshasbeendisplayed,thefault
sequencewillrepeat.Ifnoactivefaultsexist,thediagnosticlightwillash
continuouslyoncepersecond.
Fault
Code
DiagnosticLampFlash
Pattern
FaultDescription
CorrectiveAction
Thewireharness
connectorattheTEC
orattheRF2CANmodule
isloose,corroded,or
damaged
TheRF2CANmodule
circuitwiringisdamaged;
refertoAppendixA(page
A–1)
11
Flashonce–pause–ash
once,longpausethen
repeatordisplaynextfault
Communicationbetween
theTECandRF2CAN
modulehasbeenlost
RF2CANmodulemaybe
damaged,contactyour
authorizedT oroDistributor
Associatethehandheld
remote;refertothe
machineOperator’s
Manual
12
Flashonce–pause–ash
twice,longpausethen
repeatordisplaynextfault
Incompatiblesoftware
existsononeormoreof
thecontrolsystemnodes
(TEC,RF2CANmodule,
andhandheldremote)
Reloadthemachine
software,contactyour
authorizedT oroDistributor
13
Flashonce–pause–ash
threetimes,longpause
thenrepeatordisplaynext
fault
Wrongproducthandheld
remotebeingassociated
AlthoughtheProSweep
handheldremotemay
looksimilar,itcannotbe
associatedtothePro
ForceDebrisBlower
RF2CANmodule.Use
aProForcehandheld
remoteforassociation
Checkandadjusttheoil
levelasnecessary
14
Flashonce–pause–ash
fourtimes,longpausethen
repeatordisplaynextfault
EnergizetoRun(ETR)
circuitwasinterrupted
duetoalowoilpressure
conditionfor10seconds
Testtheengineoil
pressureswitchand
replaceifnecessary
Testthebatterycondition,
Chargethebatteryand
replaceifnecessary
Testtheenginevoltage
regulator/rectierand
replaceifnecessary
15
Flashonce–pause–ash
vetimes,longpausethen
repeatordisplaynextfault
EnergizetoRun(ETR)
circuitwasinterrupteddue
tolowvoltage(lessthan
5.5V)
Testtheenginealternator
andreplaceifnecessary
5.SetthekeyswitchtotheOFFposition.
Troubleshooting:GeneralOperationProblems
Page3–4
ProForce®DebrisBlower
18237SLRevA