EasyManua.ls Logo

Toro Pro Force 44552 - Nozzle Direction Switch (for Model 44554)

Toro Pro Force 44552
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NozzleDirectionSwitch(forModel44554)
g235609
Figure25
1.Nozzledirectionswitch2.T ethercontrolbox
POSITIONCLOSED
CIRCUITS
RAISEor
FORWARD
2+3,5+6
OFFNONE
LOWERor
REVERSE
2+1,5+4
Whentheleftsideofthenozzledirectionswitchispressedandheld,thenozzle
rotatesinthecounterclockwisedirection.Whentherightsideofthenozzle
directionswitchispressedandheld,thenozzlerotatesintheclockwisedirection.
Thenozzledirectionswitchislocatedonthetethercontrolbox.
TestingtheNozzleDirectionSwitch
1.Parkthemachineonalevelsurfaceandstoptheengine.
2.Disconnectthebatterynegative(-)cableatthebattery.
3.Removethetethercontrolboxcoveranddisconnectthewireharness
connectorfromtheswitch.Removetheswitchfromthecontrolboxif
necessary.
4.Useamultimeter(ohmssetting)andtheprecedingtabletodetermine
whethercontinuityexistsbetweenthevariousterminalsforeachswitch
position.
5.Replacetheswitchifnecessary.
6.Iftheswitchtestscorrectlyandacircuitproblemstillexists,checkthewire
harness;refertoAppendixA(pageA–1).
7.Installtheswitchandconnectthewireharnessaftertesting.
8.Connectthebatterynegative(-)cableatthebattery.
ProForce®DebrisBlower
Page5–21
ElectricalSystem:TestingtheElectricalComponents