g235610
Figure29
1.Relay2.T ethercontrolbox
Note:Model44554machineshaveanadditional5terminalrelaylocatedinthe
tetheredcontrolbox.Thisrelayisnotpresentlybeingused.
TestingtheRelays
1.Parkthemachineonalevelsurfaceandstoptheengine.
2.Disconnectthebatterynegative(-)cableatthebattery.
3.Locatetherelaytobetestedanddisconnectthewireharnessconnectorfrom
therelay.Removetherelayfromthecontroltowerifnecessary.
Note:Beforetakingthesmallresistancereadingswithadigitalmultimeter,
shortthemultimetertestleadstogether.Themeterdisplaysasmall
resistancevalue(usually0.5ohmsorless).Thisresistanceisbecauseofthe
internalresistanceofthemultimeterandtestleads.Subtractthisvaluefrom
themeasuredvalueofthecomponentthatyouaretesting.
g256780
Figure30
4.Testtherelayasfollows:
ProForce®DebrisBlower
Page5–25
ElectricalSystem:TestingtheElectricalComponents
18237SLRevA