Start and High Temp. Relays (Reelmaster 216-D only) (Fig. 13, 14, 15)
To test the relay, disconnect the relay wire connector
and install a continuity tester between the relay termi-
nals (terminals 30 and 87). The relay should make and
break continuity at terminals 30 and 87 as 12 V.D.C. is
connected and disconnected to terminal 85 with termi-
nal 86 connected to ground.
Figure 13
1. Start relay (Item 39)
1
Figure 14
1. High temp. relay (Item 34)
Figure 15
Testing Page 6 - 24 Reelmaster
®