Fault102:OverCurrentDisable—CRM3
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#102 _____
HI Disable 3
FaultDescription
Cuttingreelmotor3hasdetectedexcessivecurrentdrawandhasbeendisabled.
CircuitDescription
Eachcuttingreelmotorhasaninternalvoltageregulator.
ConditionsforSettingtheFault
Cuttingreelmotor3hasdetectedexcessivecurrentdrawandhasbeendisabled.
Note:ChecktheInfoCenterforfault67(SpeedStall—CRM3)orfault72(HighT empWarning—CRM3),asan
overheatedcuttingreelmotororacuttingreelmotorstallcouldbeacontributingfactortoafault102.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
2.Unplugthe48Vdcbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnecting
andDisconnectingthe48VdcBatterySystem(page19).
3.Swapcuttingreelmotor3withacuttingreelmotorfromadifferentcuttingunit.Youcanobtainmore
informationonreplacingthecuttingreelmotorinChapter5ofthe5010-HServiceManual.
4.Pluginthe48Vdcbatterydisconnect.RefertoConnectingandDisconnectingthe48VdcBatterySystem
(page19).
5.Operatethemachine.