EasyManua.ls Logo

Toro Reelmaster 5100-D - Page 166

Toro Reelmaster 5100-D
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
Diagnostic ACE Display Functions
1. Overlay decal (English shown)
2
2. “Inputs Displayed” LED (Red)
3. “Outputs Displayed” LED (Green)
3
4. Toggle button
4
Figure 8b
3
2
1
1. LED lit if oil level is too high
2.
LED lit if oil level is OK
3. LED lit if oil level is too low
Using “Inputs Displayed” (Red Text)
a.
4
5
6
4. LED lit if oil is too hot
5.
LED lit if system air leak has been
detected
6. One or two LED’s lit displaying
relative position of the Turfdefenders
internal float.
b.
7
7. “Inputs Displayed” LED “ON” (Red)
Normal Operation:
a.
“Oil Level OK” LED lit
b. 1 or 2 LED’s lit on left column
Figure 8c
Using “Outputs Displayed” (Green Text)
Normal Operation:
a. “Valve ON” LED lit steadily
b. “Self Diagnostic” LED lit steadily
c. “DATA LINE” LED lit steadily
d. “Alarm ON” LED lit temporarily
Problem Diagnosed:
The appropriate LED will blink to
identify the problem
Figure 8d
Troubleshooting
Page 5 – 8.4 Rev
. B