Starting Problems
Condition Possible Cause Correction
All electrical is dead, including Low battery charge. Charge battery
. Replace battery if
gauges. it will not hold a charge.
Thermal circuit breaker No. 1 open. Find cause for open circuit
breaker and correct. Circuit
breaker will reset automatically
after has cooled.
5A key switch fuse open. Check fuse and replace if fuse is
open. I
f fuses burn out often, find
and correct cause. NOTE: If
auxillary lights are added, this
fuse must be replaced with a
15A fuse.
Faulty key switch wiring. Repair wiring.
Faulty key switch. Test key switch and replace if
necessary
.
Starter solenoi
d clicks, but starter Low battery charge. Charge battery. Replace battery if
will not crank. (If solenoid clicks, it will not hold a charge.
p
roblem is not in interlock system
or controller.) Loose or corroded battery cables. Clean and tighten or repair as
L
oose or corroded ground. necessary.
Faulty wiring at starter. Repair wiring.
Loose starter mount
ing bolts. Clean mounting surface and
ti
ghten bolts.
Faulty starter. Repair or replace starter.
Faulty starter s
olenoid. Replace start
er solenoid.
Reelmaster
®