EasyManua.ls Logo

Toro Reelmaster 5210 - Mow Circuit Problems

Toro Reelmaster 5210
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reelmaster 5010 SeriesHydraulic System (Rev. C) Page 4 -- 24
Traction Circuit Problems (Continued)
Problem Possible Cause
Wheel motor will not turn Brakes are binding.
Wheel motor is worn or damaged.
(NOTE: If a traction circuit component has internal wear or dam-
age, it is possible that other traction components are also dam-
aged)
Wheel motors will not hold load
when traction pedal is in neutral
Charge pressure is low.
Valve plate and/or piston shoes in piston (traction) pump are
scored.
(NOTE: If a traction circuit component has internal wear or dam-
age, it is possible that other traction components are also dam-
aged)
Mow Circuit Problems
Problem Possible Cause
Front cutting unit motors will not op-
erate but rear cutting unit motors will
operate
Solenoid valve MSV2 on mow control manifold is faulty (NOTE:
Solenoid valves MSV1 and MSV2 are similar and can be reversed
for testing purposes).
Mow/backlap lever for front cutting units (MR2) not rotated fully.
An electrical problem exists that prevents MSV2 solenoid coil on
mow control manifold from being energized (see Troubleshooting in
Chapter 5 -- Electrical System).
Front cutting reel(s) is binding.
Gear pump section (P2) is worn or damaged.
Rear cutting unit motors will not op-
erate but front cutting unit motors
will operate
Solenoid valve MSV1 on mow control manifold is faulty (NOTE:
Solenoid valves MSV1 and MSV2 are similar and can be reversed
for testing purposes).
Mow/backlap lever for rear cutting units (MR1) not rotated fully.
An electrical problem exists that prevents MSV1 solenoid coil on
mow control manifold from being energized (see Troubleshooting in
Chapter 5 -- Electrical System).
Rear cutting reel(s) is binding.
Gear pump section (P1) is worn or damaged.
Single cutting unit motor will not op-
erate or rotates slowly
Cutting unit motor is worn or damaged.
Cross-over relief valve in cutting unit motor is stuck or faulty (Reel-
master 5510 and 5610 machines).

Table of Contents

Other manuals for Toro Reelmaster 5210

Related product manuals