BeltMaintenance
ServicingtheAlternator
Belt
ServiceInterval:Aftertherst10hours
Every100hours
Note:Forproperbelttension,allow10mm(3/8inch)
deectionwhenaforceof44N(10lb)isappliedon
thebeltmidwaybetweenthepulleys.
1.Ifthedeectionisnot10mm(3/8inch),loosen
thealternatormountingbolts(Figure144).
g020537
Figure144
1.Mountingbolt2.Alternator
2.Increaseordecreasethealternator-belttension
andtightenthebolts.
3.Checkthedeectionofthebeltagaintoensure
thatthetensioniscorrect.
HydraulicSystem
Maintenance
HydraulicSystemSafety
•Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
•Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
•Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
•Usecardboardorpapertondhydraulicleaks.
•Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
HydraulicFluid
Specications
Thereservoirislledatthefactorywithhigh-quality
hydraulicuid.Checkthelevelofthehydraulicuid
beforeyourststarttheengineanddailythereafter;
refertoCheckingtheHydraulic-FluidLevel(page82).
Recommendedhydraulicuid:ToroPXExtended
LifeHydraulicFluid;availablein19L(5USgallon)
pailsor208L(55USgallon)drums.
Note:Amachineusingtherecommended
replacementuidrequireslessfrequentuidandlter
changes.
Alternativehydraulicuids:IfT oroPXExtended
LifeHydraulicFluidisnotavailable,youmayuse
anotherconventional,petroleum-basedhydraulicuid
havingspecicationsthatfallwithinthelistedrange
forallthefollowingmaterialpropertiesandthatit
meetsindustrystandards.Donotusesyntheticuid.
Consultwithyourlubricantdistributortoidentifya
satisfactoryproduct.
Note:T orodoesnotassumeresponsibilityfor
damagecausedbyimpropersubstitutions,souse
productsonlyfromreputablemanufacturerswhowill
standbehindtheirrecommendation.
HighViscosityIndex/LowPourPoint
Anti-wearHydraulicFluid,ISOVG46
MaterialProperties:
Viscosity,ASTMD445cSt@40°C(104°F)
44to48
81