Reelmaster 5500-DHydraulic System (Rev. C) Page 4 - 50
8. Install transmission control linkage to the transmis-
sion (see Transmission Control Linkage Installation).
9. Secure suction line to top of in-line filter (Fig. 35).
10.Install two (2) rear cutting units (see Chapter 8 - Cut-
ting Units).
11.Install a new filter and fill differential with correct oil.
12.Disconnect fuel stop solenoid electrical connector on
engine to prevent engine from starting. Prime transmis-
sion by turning ignition key switch to crank engine for 10
seconds. Repeat cranking procedure again.
13.Start the engine and let it idle for approximately two
minutes. Operate machine slowly in forward and re-
verse. Stop engine and check differential oil level.
Check transmission for leaks.