Reelmaster 6500D/6700–D
Page 4 28
Hydraulic System
Cutting Units Raise, But Will Not Stay Up
NOTE: Lift cylinders and check valves cannot provide
an absolutly perfect seal. The lift arms will eventually
lower if left in the raised position during storage. It is rec-
ommended that the machine be stored with the cutting
units in the lowered position. This also prevents acci-
dental lowering of the cutting units if the lift lever (joy-
sitck) is bumped while the key switch is on.
Cause
Correction
S5A leaking down (not seating properly).
Reelmaster 6700D only S6B affects No. 6 and 7
cutting units.
Do cartridge valve service procedure for valve S5A.
Replace S5A with a new valve if faulty.
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Excessive internal leakage in lift cylinder(s).
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Check lift cylinder(s) and repair or replace if faulty.
Front Outer Cutting Units Lower Too Fast or Too Slow
Cause Correction
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
One-way variable orifice not properly adjusted (#4 and
#5 cutting units only) - see Hydraulic Schematics.
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Adjust variable orifice for affected circuit.
Cutting Units Will Not Lower
Cause Correction
S5A not shifting.
Reelmaster 6700D only S6B affects No. 6 and 7
cutting units.
Do electrical diagnostics to make sure that voltage is
being applied to solenoid for affected circuit and that
there is no electrical fault. See Chapter 5 Electrical
System.
Do cartridge valve service procedure for valve S5A.