excessiveheat,causedamagetosealsandothercomponentsinthehydraulic
system,andaffectoverallmachineperformance.
SpecialEquipmentRequired:
PressureGauge(accuratebelow300psi)
Flowmeterwithpressuregaugethathasatleasta57liters/minute(15
gallons/minute)capacity
Hydraulictesthose
Non-contacttachometer(phototach)
TestProcedure
1.Parkthemachineonalevelsurface,loweranyattachments,engagethe
parkingbrake,andsetthekeyswitchtotheOFFposition.
2.ReadandadheretotheinformationprovidedinT estingtheHydraulicSystem
(page5–23).
3.EnsurethatthetractionpedaliscorrectlyadjustedfortheNEUTRALposition;
refertoAdjustingtheTractionSystemforNeutral(page5–52).
4.Removethecentershroud.
5.Removethe3screwsthatsecurethedashpaneltothemachine,then
carefullyraisethedashpaneltoaccesstherearfueltankclamps.Remove
therearfueltankclamps.
g354938
Figure31
1.Centershroud3.Rearfueltankclamp(2each)
2.Dashshroud4.Dashpanel
6.Removethefastenersatthebottomofthedashshroudandremovethe
dashshroudfromthemachine.
7.Cleanthettingsandthehydraulicabovethefrontwheelandontheleftside
ofthehydraulicuidcooler;refertoFigure32.
HydraulicSystem:TestingtheHydraulicSystem
Page5–28
SandPro
®
3040and5040
20251SLRevA