EasyManua.ls Logo

Toro Z Master Professional 7500-D Series - Checking the Alternator-Belt Tension

Toro Z Master Professional 7500-D
Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g243947
Figure62
1.Spring-loadedidlerpulley3.Spring
2.Squareholeintheidler
armfortheratchet
4.Centerdeckmowerbelt
7.Installthenewbeltaroundthemowerdeck
pulleys.
8.Installthe2wingdecksbelts;refertoReplacing
theWingDeckBelts(page59).
9.Installthebeltcoversandoorboard.
Checkingthe
Alternator-BeltTension
ServiceInterval:Every100hours
1.Apply44N(10lb)offorcetothealternatorbelt,
midwaybetweenthepulleys.
2.Ifthedeectionisnot10mm(3/8inch),loosen
thealternatormountingbolts(Figure63).
g008932
Figure63
1.Mountingbolt2.Alternator
3.Increaseordecreasethealternator-belttension.
4.Tightenthemountingbolts.
5.Checkthedeectionofthebeltagaintoensure
thatthetensioniscorrect.
60