5-27Z Master Z597 Diesel Service Manual
5
8. Install the engine inlet house and tighten the clamp
(Fig. 317).
Fig 317 DSC-2425
9. Close the radiator petcock.
10. Fill the radiator with 50/50 mix of extended life
antifreeze/Dex-Cool and water.
Check the antifreeze overow bottle and make sure
it is up to indicator line.
Cooling system capacity: 128 ounces (3.8l)
11. Check the hydraulic reservoir tank to make sure the
uid level is at the cold level mark.
12. Connect the negative battery cable. Start the unit
up and operate for about 5 minutes. Observe all the
cooling and hydraulic lines for any leaks.
13. Recheck the hydraulic reservoir tank at the hot level
mark; add oil if necessary. Also, recheck the coolant
level in the overow bottle.
14. Install the right and left hair pins to the clevis pins
that hold the engine hood assembly (Fig. 318).
Fig 318 DSC-2411
15. Slide the right and left hood lanyards on the radiator
support bolts (Fig. 319).
Fig 319 DSC-2410
ENGINE