UPS Start-up Screens
The LCD will automatically display the basic system start-up functions when AC input power is turned
on to the unit (see "Starting the UPS on page 39). The basic start-up functions system function indicate
the operating state of the unit. If the correct ac input power is available and no abnormal operating
conditions are present then the following system message will be displayed on the LCD screen:
The LCD will automatically and sequentially display on the first line that the UPS is in bypass operation
mode and the second line will display the percentages of maximum load that are connected. The left
value is the phase U load and the right value is the phase V load. This screen will continue to be
displayed until the key is pressed unless the automatic operation (see 'auto run' page 30) is set
to "Y". If the connected loads are varied then the load percentages will change. The UPS inverter is not
"on" and running and if the AC input power is removed from the unit the output will stop:
The LCD will automatically and sequentially display the date function on the first line and the time
function on the second line. The following screen is an example. The correct date and time can be
set (see Date Time function setting on page 30):
The UPS operation starts immediately when the key is pressed or will start if the automatic
operation is set to turn it on (see 'auto run' data setting screen on page 30). The LCD will automatically
display on the first line that the UPS is in the normal operation mode and the second line will display
the percentages of maximum load that are connected. The left value is the phase U load and the right
value is the phase V load:
The LCD will automatically and sequentially display on the first line that the UPS is in normal operation
mode. The second line will display the percentages of maximum load that are connected. The left value
is the phase U load and the right value is the phase V load.
The UPS internal batteries are automatically tested and the following screen appears while the testing
is being done. The first line indicates that a battery test is occurring. The second line indicates the
present battery voltage level as a percentage of full charge:
Note: If input voltage is removed
while UPS is in this state then the
output stops.
Display Screens
BYPASS OPERATION
LOAD ##%/##%
UPS OPERATION
LOAD ##%/##%
11/04/1999(WED)
15:22:47
BATTERY TEST
BAT VOLTAGE ##%
TOSHIBA 1600 UPS
INITIALIZING...
UPS OPERATION
LOAD ##%/##%