EasyManua.ls Logo

Toshiba 1600 Series - Data Setting Procedures; Key Lock Functionality; Buzzer Volume Adjustment; LCD Sleep Time Configuration

Toshiba 1600 Series
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KEYLOCK:EN
TO ACCEPT:SET
KEYLOCK:DIS
TO ACCEPT:SET
Loops through both
possibilities
+
KEY LOCK:DIS
TO CHANGE:SELECT
KEY LOCK:EN
TO CHANGE:SELECT
Returns to
Data Setting Screens
(with new value
applied)
Cont'd from Key Lock
Data Setting Screen page 30
BUZZER VOLUME:0
TO ACCEPT:SET
BUZZER VOLUME:2
TO ACCEPT:SET
BUZZER VOLUME:2
TO CHANGE:SELECT
BUZZER VOLUME:0
TO CHANGE:SELECT
BUZZER VOLUME:1
TO ACCEPT:SET
BUZZER VOLUME:1
TO CHANGE:SELECT
Returns to
Data Setting Screens
(with new value
applied)
Loops through three
possibilities
Cont'd from Buzzer
Data Setting Screen page 30
LCD SLEEP:30MIN
TO ACCEPT:SET
LCD SLEEP:3MIN
TO ACCEPT:SET
Loops through both
possibilities
LCD SLEEP:3MIN
TO CHANGE:SELECT
LCD SLEEP:30MIN
TO CHANGE:SELECT
Returns to
Data Setting Screens
(with new value
applied)
Cont'd from LCD display Time
Data Setting Screen page 30
AUTO RUN:NO
TO ACCEPT:SET
AUTO RUN:YES
TO ACCEPT:SET
Loops through both
possibilities
AUTO RUN:Y
TO CHANGE:SELECT
AUTO RUN:N
TO CHANGE:SELECT
Returns to
Data Setting Screens
(with new value
applied)
Cont'd from Auto Run
Data Setting Screen page 30
31
TOSHIBA
+
+
+
+
+
+
+
+
Display Screens (cont'd)
Data Setting Screens
The following screens show the setting procedure for setting the data variables. They are accessed
from the main 'data setting screens' (see page 30) when the key is pressed:
General
Safety
Inspections &
Precautions
Connections
Equipment
Equipment
Specifications
EquipmentDisplay
Screens
Manual
Run/Stop
Protection
System
Maintenance
& Options
Dimensions &
Weights
Index
Reference
Operations
Key Functions
Display &
The Keylock function allows the operator
to disable the RUN + STOP button functions.
When this function is set to EN the unit will
remain in the operating mode it was in when
enabled and will not be able to be changed
with the RUN + STOP buttons until this
function is disabled.
With this function set to DIS, the RUN +
STOP buttons function normally.
The default setting is DIS.
2 = High
1 = Low
0 = Off
Default setting is 2 = High (loudest)
Displays the number of minutes (3 or 30) of
idle time before the LCD will go blank (this is
to prolong LCD life). The LCD will be active
again once a display button is pressed.
Default setting is 3 min.
If set to YES, the unit will automatically
start up in the UPS mode (on line) when
input voltage is applied, regardless of what
mode it was in when shut down.
Default setting is NO.
Shift
Select
Shift
Select
Shift
Select
Shift
Select
Shift
Select
Shift
Select
Shift
Select
Shift
Select
Shift
Select
Set
Monitor
Set
Monitor
Set
Monitor
Set
Monitor
Set
Monitor
Set
Monitor
Set
Monitor
Set
Monitor
Set
Monitor
Shift
Select

Other manuals for Toshiba 1600 Series