EasyManua.ls Logo

Toshiba 27WL56P - Page 9

Toshiba 27WL56P
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
9
-
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s is executed properly.
2) During diagnosis, the following displays are shown.
1 Firmware :
Version information of microprocessor
In case of file name : WL56_EU and Version : 0100 indicates[WL56_EU_0100].
2 Time : Total hour of turn the TV on. (Unit : H)
3 Power :Operation number of protecting circuit ----"000" is normal.
When indication is other than "000", overcurrent apt to flow, and circuit parts may possibly be damaged.
4 Bus line : --"OK" is normal
"SCL-GND"(Red indication) : SCL-GND short circuit
"SDA-GND"(Red indication) : SDA-GND short circuit
"SCL-SDA"(Red indication) : SCL-SDA short circuit
5 Bus cont : --- "OK" is normal.
NG is abnormal(Red indication).
When type name of semiconductor indicates.
6 Block
UV : TV reception mode
V1 : VIDEO 1 input mode ( 1)
V2 : VIDEO 2 input mode ( 2)
V3 : VIDEO 3 input mode ( 3)
V4 : VIDEO 4 input mode ( HDMI)
7 8 digit : CD number
8 Model name (7 digit)
000
000000
27WL56P
27WL56P
WL56_EU_0100
WL56_EU_0100
1
2
3
4
5
6
78